SCHNEIDER: LTM R08MBD

Tình trạng sản phẩm: mới

10.000.000

Rơ le Tesys-T: Bộ điều khiển Modbus 0.4 8A 24VDC

Xuất xứ: Trung Quốc

Mua nhanh

Mô tả

range
TeSys
product name
TeSys T
device short name
LTMR
product or component type
Motor controller
device application
Equipment monitoring and control
measurement current
0.4…8 A
[Us] rated supply voltage
24 V DC
current consumption
56…127 mA
supply voltage limits
20.4…26.24 V DC
communication port protocol
Modbus
bus type
Modbus 2-wire RS 485 interface, addressing 1…247, transmission rate 1.2…19.2 kbit/s, RJ45 with 2 shielded twisted pairs
Modbus 2-wire RS 485 interface, addressing 1…247, transmission rate 1.2…19.2 kbit/s, terminal block with 2 shielded twisted pairs
Complementary
[Ui] rated insulation voltage
690 V conforming to CSA C22.2 No 14
690 V conforming to EN/IEC 60947-1
690 V conforming to UL 508
[Uimp] rated impulse withstand voltage
6 kV for current or voltage measurement circuit conforming to EN/IEC 60947-4-1
0.8 kV for communication circuit conforming to EN/IEC 60947-4-1
0.8 kV for supply, inputs and outputs conforming to EN/IEC 60947-4-1
short-circuit withstand
100 kA conforming to EN/IEC 60947-4-1
associated fuse rating
0.5 A gG for control circuit
4 A gG for output
protection type
Earth-leakage protection
Phase failure
Reverse polarity protection
Thermal overload protection
Thermal protection
Overload
Phase unbalance
Locked rotor
Overload (long time)
Load fluctuation
Power factor variation
network and machine diagnosis type
Phase fault and earth fault trip counters
Remaining operating time before overload tripping
Running hours counter/operating time
Starting current and time
Waiting time after overload tripping
Fault recording
Event recording
Trip context information
Trip history information
Motor control command recording
logic input number
6
input current
7 mA
current state 0 guaranteed
Logic input : < 5 V and <= 15 mA for 5 ms
current state 1 guaranteed
Logic input : < 15 V and 2…15 mA for 15 ms
maximum operating frequency
2 Hz
load current
5 A at 250 V AC for logic output
5 A at 30 V DC for logic output
permissible power
480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
operating rate
1800 cyc/h
contacts type and composition
1 NO + 1 NC fault signal
3 NO
metering type
Earth-fault current
Phase current I1, I2, I3 RMS
Temperature
Average current Iavg
Imbalance current
measurement accuracy
3 % power factor (cos φ > 0.6)
+/- 30 min/year internal clock
0,02 temperature
5…15 % earth fault current internal measurement (for current > 0.1 A)
1 % current
1 % voltage (100…830 V)
5 % active and reactive power
5 % earth fault current external measurement (< 5 % or 0.01 A)
overvoltage category
III
connection pitch
5.08 mm
connections – terminals
Connector, 1 flexible cable with cable end 0.25…2.5 mm² /AWG 24…AWG 14 for control circuit
Connector, 1 flexible cable without cable end 0.2…2.5 mm² /AWG 24…AWG 14 for control circuit
Connector, 1 flexible cable without cable end 0.25…2.5 mm² /AWG 24…AWG 14 for control circuit
Connector, 1 solid cable without cable end 0.2…2.5 mm² /AWG 24…AWG 14 for control circuit
Connector, 2 flexible cable with cable end 0.2…1 mm² /AWG 24…AWG 14 for control circuit
Connector, 2 flexible cable without cable end 0.2…1.5 mm² /AWG 24…AWG 14 for control circuit
Connector, 2 flexible cable without cable end 0.5…1.5 mm² /AWG 24…AWG 14 for control circuit
Connector, 2 solid cable without cable end 0.2…1 mm² /AWG 24…AWG 14 for control circuit
tightening torque
0.5…0.6 N.m, 3 mm flat screwdriver for control circuit
pollution degree
3
electromagnetic compatibility
● electrostatic discharge 3 (8 kV air, 6 kV contact), conforming to EN/IEC 61000-4-2
● fast transients immunity test other circuits level 3 (2 kV), conforming to EN/IEC 61000-4-4
● fast transients immunity test on supply and relay outputs level 4 (4 kV), conforming to EN/IEC 61000-4-4
● conducted RF disturbances (10 V), conforming to EN/IEC 61000-4-6
● surges common mode (1 kV) control circuit, conforming to EN/IEC 61000-4-5
● surges serial mode (1 kV) control circuit, conforming to EN/IEC 61000-4-5
● surges common mode (2 kV) communication, conforming to EN/IEC 61000-4-5
● radiated RF fields 3 (10 V/m), conforming to EN/IEC 61000-4-3
● voltage dips and interruptions immunity test (70 %, 500 ms), conforming to EN/IEC 61000-4-11
● surges serial mode (0.5 kV) temperature sensor, conforming to EN/IEC 61000-4-5
● surges common mode (1 kV) temperature sensor, conforming to EN/IEC 61000-4-5
● surges serial mode (2 kV) relay outputs and supply, conforming to EN/IEC 61000-4-5
● surges common mode (4 kV) relay outputs and supply, conforming to EN/IEC 61000-4-5
width
91 mm
height
61 mm
depth
122.5 mm
product weight
0.53 kg
web services
Web server
compatibility code
LTMR

Thông tin bổ sung

HÃNG SX

TÌNH TRẠNG

Đánh giá

Chưa có đánh giá nào.

Hãy là người đầu tiên nhận xét “SCHNEIDER: LTM R08MBD”

Email của bạn sẽ không được hiển thị công khai. Các trường bắt buộc được đánh dấu *