Mô tả
range |
TeSys
|
|
---|---|---|
product name |
TeSys D
|
|
product or component type |
Contactor
|
|
device short name |
LC1D
|
|
contactor application |
Motor control
Resistive load |
|
utilisation category |
AC-1
AC-3 AC-4 |
|
poles description |
3P
|
|
pole contact composition |
3 NO
|
|
[Ue] rated operational voltage |
<= 300 V DC for power circuit
<= 1000 V AC 25…400 Hz for power circuit |
|
[Ie] rated operational current |
200 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
150 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit |
|
motor power kW |
40 kW at 220…230 V AC 50/60 Hz AC-3
75 kW at 380…400 V AC 50/60 Hz AC-3 80 kW at 415…440 V AC 50/60 Hz AC-3 90 kW at 500 V AC 50/60 Hz AC-3 100 kW at 660…690 V AC 50/60 Hz AC-3 75 kW at 1000 V AC 50/60 Hz AC-3 22 kW at 400 V AC 50/60 Hz AC-4 |
|
motor power hp |
40 hp at 200/208 V AC 50/60 Hz for 3 phases motors
50 hp at 230/240 V AC 50/60 Hz for 3 phases motors 100 hp at 460/480 V AC 50/60 Hz for 3 phases motors 125 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
|
control circuit type |
AC 50/60 Hz
|
|
[Uc] control circuit voltage |
220 V AC 50/60 Hz
|
|
auxiliary contact composition |
1 NO + 1 NC
|
|
[Uimp] rated impulse withstand voltage |
Conforming to IEC 60947
|
|
overvoltage category |
III
|
|
[Ith] conventional free air thermal current |
200 A at <= 60 °C for power circuit
|
|
Irms rated making capacity |
1660 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
|
rated breaking capacity |
1400 A at 440 V for power circuit conforming to IEC 60947
|
|
[Icw] rated short-time withstand current |
100 A 1 s signalling circuit
120 A 500 ms signalling circuit 140 A 100 ms signalling circuit 250 A <= 40 °C 10 min power circuit 580 A <= 40 °C 1 min power circuit 1200 A <= 40 °C 10 s power circuit 1400 A <= 40 °C 1 s power circuit |
|
associated fuse rating |
250 A gG at <= 690 V coordination type 2 for power circuit
315 A gG at <= 690 V coordination type 1 for power circuit 10 A gG for signalling circuit conforming to IEC 60947-5-1 |
|
average impedance |
0.6 mOhm at 50 Hz – Ith 200 A for power circuit
|
|
[Ui] rated insulation voltage |
1000 V for power circuit conforming to IEC 60947-4-1
600 V for power circuit certifications CSA 600 V for power circuit certifications UL 690 V for signalling circuit conforming to IEC 60947-1 600 V for signalling circuit certifications CSA 600 V for signalling circuit certifications UL |
|
electrical durability |
0.85 Mcycles 150 A AC-3 at Ue <= 440 V
1 Mcycles 200 A AC-1 at Ue <= 440 V |
|
power dissipation per pole |
24 W AC-1
13.5 W AC-3 |
|
protective cover |
With
|
|
mounting support |
Plate
Rail |
|
standards |
CSA C22.2 No 14
EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 |
|
product certifications |
BV
CCC CSA DNV GL GOST LROS (Lloyds register of shipping) RINA UL |
|
connections – terminals |
Control circuit : screw clamp terminals 2 cable(s) 1…2.5 mm² – cable stiffness: flexible – without cable end
Control circuit : screw clamp terminals 2 cable(s) 1…2.5 mm² – cable stiffness: flexible – with cable end Control circuit : screw clamp terminals 2 cable(s) 1…2.5 mm² – cable stiffness: solid – without cable end Control circuit : screw clamp terminals 1 cable(s) 1…2.5 mm² – cable stiffness: flexible – with cable end Control circuit : screw clamp terminals 1 cable(s) 1…2.5 mm² – cable stiffness: flexible – without cable end Control circuit : screw clamp terminals 1 cable(s) 1…2.5 mm² – cable stiffness: solid – without cable end Power circuit : connector 1 cable(s) 10…120 mm² – cable stiffness: flexible – without cable end Power circuit : connector 2 cable(s) 10…50 mm² – cable stiffness: flexible – without cable end Power circuit : connector 1 cable(s) 10…120 mm² – cable stiffness: flexible – with cable end Power circuit : connector 2 cable(s) 10…50 mm² – cable stiffness: flexible – with cable end Power circuit : connector 1 cable(s) 10…120 mm² – cable stiffness: solid – without cable end Power circuit : connector 2 cable(s) 10…50 mm² – cable stiffness: solid – without cable end |
|
tightening torque |
Control circuit : 1.2 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit : 1.2 N.m – on screw clamp terminals – with screwdriver Philips No 2 Power circuit : 12 N.m – on connector hexagonal 4 mm |
|
operating time |
20…35 ms closing
40…75 ms opening |
|
safety reliability level |
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
|
mechanical durability |
8 Mcycles
|
|
operating rate |
1200 cyc/h at <= 60 °C
|
coil technology |
Built-in bidirectional peak limiting diode suppressor
|
|
---|---|---|
control circuit voltage limits |
0.3…0.5 Uc drop-out at 55 °C, AC 50/60 Hz
0.8…1.15 Uc operational at 55 °C, AC 50/60 Hz |
|
inrush power in VA |
280…350 VA at 20 °C (cos ϕ 0.9) 60 Hz
280…350 VA at 20 °C (cos ϕ 0.9) 50 Hz |
|
hold-in power consumption in VA |
2…18 VA at 20 °C (cos ϕ 0.9) 60 Hz
2…18 VA at 20 °C (cos ϕ 0.9) 50 Hz |
|
heat dissipation |
3…4.5 W at 50/60 Hz
|
|
auxiliary contacts type |
Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
Type mirror contact (1 NC) conforming to IEC 60947-4-1 |
|
signalling circuit frequency |
25…400 Hz
|
|
minimum switching current |
5 mA for signalling circuit
|
|
minimum switching voltage |
17 V for signalling circuit
|
|
non-overlap time |
1.5 ms on de-energisation (between NC and NO contact)
1.5 ms on energisation (between NC and NO contact) |
|
insulation resistance |
> 10 MOhm for signalling circuit
|
IP degree of protection |
IP20 front face conforming to IEC 60529
|
|
---|---|---|
protective treatment |
TH conforming to IEC 60068-2-30
|
|
pollution degree |
3
|
|
ambient air temperature for operation |
-5…60 °C
|
|
ambient air temperature for storage |
-60…80 °C
|
|
permissible ambient air temperature around the device |
-40…70 °C at Uc
|
|
operating altitude |
3000 m without derating in temperature
|
|
fire resistance |
850 °C conforming to IEC 60695-2-1
|
|
flame retardance |
V1 conforming to UL 94
|
|
mechanical robustness |
Vibrations contactor open 2 Gn, 5…300 Hz
Vibrations contactor closed 4 Gn, 5…300 Hz Shocks contactor closed 15 Gn for 11 ms Shocks contactor open 6 Gn for 11 ms |
|
height |
158 mm
|
|
width |
120 mm
|
|
depth |
136 mm
|
|
product weight |
2.5 kg
|
Sustainable offer status |
Green Premium product
|
|
---|---|---|
RoHS (date code: YYWW) |
Schneider Electric declaration of conformity
|
|
REACh |
Reference not containing SVHC above the threshold
|
|
Product environmental profile |
Product environmental
|
|
Product end of life instructions |
End of life manual
|
Đánh giá